UPS COVER WINTER 3K

COVER Line-Interactive, 3kVA/2.7kW uninterruptible power supply. Plug@Play. Phase configuration 1:1. Rack/Tower cabinet (without batteries). Sinusoidal output voltage waveform for battery operation.

11-WNT0-0030

CHARACTERISTICS

  • True OnLine technology (VI according to IEC62040) ensuring sinusoidal shape of output voltage in both normal and battery operation while maintaining very high efficiency and quiet operation.
  • Communication:
  • - USB 2.0, RS-232 for monitoring and managing the operation of the power supply and receivers. ViewPower communication software for advanced management of power supply operation and receivers as standard.
  • - An expansion card slot allows the connection of an SNMP card to manage the UPS from the network or an AS-400 card with additional non-voltage signals to inform the BMS of the UPS operation status.
  • - TVSS surge protection is a guarantee of the safety of data transmitted over the network thanks to built-in RJ-45 protection ports.
  • LCD Panel clearly informs you about the operating mode, power supply parameters and allows you to configure UPS parameters. Depending on the operating position of the power supply (Towe/Rack), the LCD panel allows you to rotate for easy reading of parameters including I/O voltage, battery voltage, load and battery charge level, autonomy time and power supply operating configuration.
  • Compact dimensions UPS and also an external battery module. The height of just 2U provides minimal installation space.
  • High efficiency of the device Up to 97% in normal mode minimizes energy consumption and reduces emitted heat making eventual cooling cheaper.
  • Automatic diagnostics guarantees the full efficiency of the device, control of components and operating parameters without user intervention.
  • Wide input voltage tolerance range for normal operation means that the use of batteries by the UPS is limited to the minimum necessary, practically only in cases of complete power failure.
  • Ability to extend autonomy time By adding external battery modules.
  • Quick HotSwap battery replacement During operation of the device. It eliminates the need to turn off receivers and guarantees trouble-free operation.
  • High output power factor (PF=0.9) guarantees up to 50% more active power compared to other power supplies in this class, allowing more devices to be connected.
  • Autorestart guarantees maintenance-free operation of the device in case of long power outages.
  • Battery start (so-called cold start) gives you the ability to start the power supply even in the event of a complete lack of supply voltage.
  • Advanced battery management guarantees optimal charging and utilization of battery banks, extends battery life by up to 50% and reduces operating costs.
  • Excellent voltage quality sinusoidalny przebieg napięcia zarówno w pracy normalnej jak też w trybie bateryjnym. Duża stabilność napięcia wyjściowego w stanach dynamicznych.
  • Overload resistance is the certainty of power supply in the presence of transients and high tolerance to operating errors.
  • Advanced software enabling the user to have full control over the device and the powered loads
  • EPO connector provides the ability to remotely shut down the power supply in case of fire (fire shutdown)
  • Controlled output socket groups allow you to manage the presence of output voltage locally or remotely over the network. They allow you to determine the priority of switching off the voltage on a given group of outlets during battery operation and give you the ability to perform a remote restart of devices connected to the UPS output (e.g. switch, router).

BACKUP TIME

Internal batteries Load Backup time [min]
WINTER 3000
6 x 9Ah 100% 4
75% 6
50% 11
25% 28

EBM CORE 3K Load Backup time [min]
WINTER 3000
UPS + 1xEBM (3 x 6 x 9Ah) 100% 22
75% 31
50% 51
25% 138
UPS + 2xEBMs (5 x 6 x 9Ah) 100% 42
75% 57
50% 107
25% 213
UPS + 3xEBMs (7 x 6 x 9Ah) 100% 60
75% 90
50% 160
25% 360

TECHNICAL SPECIFICATIONS

Model WINTER 3000
Power 3kVA / 2,7kW
Phases In/Out 1:1
Input
Nominal voltage 208 / 220 / 230 / 240 Vac
Voltage range 162÷290 Vac
Nominal frequency 50 / 60Hz
Frequency range 45 ÷ 65Hz
Output
Nominal voltage 208 / 220 / 230 / 240 Vac
Power factor 0.9
Voltge regulation static/dynamic ±1,5% (praca bateryjna)
Nominal frequency 50 / 60 ± 1 Hz
Overloads capability 120% - 5min., 150%- 10s., >150% - 1s.
Efficiency in OnLine mode >97%
Switching time 2÷6ms
Output sockets 8 x IEC 320 C13
1 x IEC 320 C19
Batteries
Cold start Yes
Internal batteries possibility 6 x 9Ah/12V
Nominal voltage 72Vdc
Charger curent 1,5A
Charging time 3 – 8 hours up to 90% capacity (configurable)
Charging cycle According to DIN 41773 with automatic charging shutdown according to current and voltage criteria, with time control.
Dimensions and weights
Dimensions (S x G x W) 438 x 630 x 88mm (2U)
Weight 29,3 kg
Signaling and communication ports
Operating status indicator LCD + audible alarm
Communication RS232, USB, TVSS, EPO, slot SNMP
Environmental conditions
Noise level <45 dB
Operating temperature for UPS 0°C ÷ 40°C
Recommended operating temperature 15°C ÷ 25°C
Storage temperature -20°C ÷ 40°C
Humidity 0 ÷ 95% (non-condensing)
Cerifications
Interference immunity EN 62040-2:2017, EN 62040-2:2016, EMC, CE
Safety EN 62040-1: 2017, EN 62040-3: 2011, LVD, CE
Environmental compatibility EN IEC 63000: 2018, EN 62321, RoHS
Optional accesories
- SNMP card
- RS485 card (Modbus)
- AS 400 mini (dry-contact) card
- Environmental sensor (EMD)
- Rail kits for Rack 19'' (Rail kit)
- Remote Emergency Power Off button
- Remote LCD panel

Due to constant product improvement all specifications are subject to change without notice.

Apparent power [kVA]
3
Active power [kW]
2,7
Technology:
VI-SS-111 (LineInteactive)
Phase In/Out:
1:1
Output PF:
0,9
Max internal batteries
6